A sample built from fictional records: every company, unit and date below is made up. Your reports carry your own records. Back to Emergency Lighting Log

Sample company (fictional) · Emergency Lighting LogDraft generated Oct 30, 2026

Twelve-month emergency lighting log

Monthly 30-second

Record

CompanySample company (fictional)
TradeEmergency Lighting Log
TestMonthly 30-second

Fixture

Fixture IDLocationKindInstall dateBattery replaced on
UN-4100North bayBattery lightOct 10, 2026Oct 10, 2026

Test

Test typeTest dateTester nameMinutes run on batteryResultWhat failed
Monthly 30-secondSep 30, 2026Tester name 11 minutePassFA-4100
Monthly 30-secondDec 24, 2025Tester name 4115 minutesPassFA-5580
Monthly 30-secondFeb 22, 2026Tester name 8110 minutesPassFA-7060

Monthly

Test button or a power interruption brings the unit on at oncePass
Every lamp head is lit and aimed correctlyPass
Exit sign is illuminatedPass
Charge indicator shows a healthy statePass
Self-diagnostic units: status indicator reviewedPass

Annual

Unit ran on battery for the whole test with no dimmingPass
Battery, terminals and housing free of damage and corrosionPass
Unit mounted securely and not blockedPass

Rules this record is kept under

The monthly test runs at least 30 seconds, with 3 to 5 weeks between tests.
Maintenance of Battery-Operated Emergency Lights (Minnesota Dept of Health) (https://www.health.mn.gov/facilities/regulation/engineering/lscbatopliting.pdf), checked 2026-10-28
For reference
The annual test runs on battery for at least 90 minutes,.
Maintenance of Battery-Operated Emergency Lights (Minnesota Dept of Health) (https://www.health.mn.gov/facilities/regulation/engineering/lscbatopliting.pdf), checked 2026-10-28
Warned at save
The equipment has to stay fully working through the whole test, for the full duration.
Maintenance of Battery-Operated Emergency Lights (Minnesota Dept of Health) (https://www.health.mn.gov/facilities/regulation/engineering/lscbatopliting.pdf), checked 2026-10-28
For reference
Written test records are kept so the fire official can inspect them.
Maintenance of Battery-Operated Emergency Lights (Minnesota Dept of Health) (https://www.health.mn.gov/facilities/regulation/engineering/lscbatopliting.pdf), checked 2026-10-28
For reference
In Minnesota the state fire code keeps these records on the premises for at least 3 years. This is a state rule; check your own jurisdiction.
Maintenance of Battery-Operated Emergency Lights (Minnesota Dept of Health) (https://www.health.mn.gov/facilities/regulation/engineering/lscbatopliting.pdf), checked 2026-10-28
For reference
Each record shows whether the unit passed or failed.
Maintenance of Battery-Operated Emergency Lights (Minnesota Dept of Health) (https://www.health.mn.gov/facilities/regulation/engineering/lscbatopliting.pdf), checked 2026-10-28
For reference

Signature

The signature drawn on the phone at the job prints here.

Next due

Monthly functional test
Maintenance of Battery-Operated Emergency Lights (Minnesota Dept of Health) (https://www.health.mn.gov/facilities/regulation/engineering/lscbatopliting.pdf), checked 2026-10-28
Oct 30, 2026Set by rule
Annual 90-minute test
Maintenance of Battery-Operated Emergency Lights (Minnesota Dept of Health) (https://www.health.mn.gov/facilities/regulation/engineering/lscbatopliting.pdf), checked 2026-10-28
Oct 30, 2026Set by rule