A sample built from fictional records: every company, unit and date below is made up. Your reports carry your own records. Back to Slings & Rigging

Sample company (fictional) · Slings & RiggingDraft generated Oct 31, 2026

Alloy steel chain sling inspection

Aug 21, 2026

Record

CompanySample company (fictional)
TradeSlings & Rigging
InspectionAug 21, 2026

Customer

NameCedar Row Properties
Emailjordan@example.com
Phone555-0111
Address137 Linden Ave, Springfield

Site

NameJordan Pike
Address137 Linden Ave, Springfield
Location44.050999999999995, -123.09100000000001

Sling

Sling ID or serialSling ID or serial 2
Sling typeWire rope
Size (rope diameter or web width)Size (rope diameter or web width) 2
Chain size3/8 in
Rated capacity, vertical hitch8 lb
StatusRemoved from service
Identification marking affixed and legibleNo
Chain gradeChain grade 2
Reach or lengthReach or length 2
ManufacturerTollin Industrial
Placed in serviceAug 19, 2026
Thorough inspection interval (chain)9 months
Periodic inspection interval (other slings)9 months

Inspection

Inspected onAug 21, 2026
InspectionBefore use
Competent personJordan Pike
ResultDamaged or defective
DispositionRemoved from service
ID read from the tagTA-4137

Before use

Identification marking affixed and legiblePass
Sling, fastenings and attachments free of damage or defectsFail
Not shortened with knots, bolts or other makeshift devicesPass
Legs not kinkedPass

Chain

Links not worn below the minimum chain sizePass
No defective weldsPass
No deformation or increase in lengthPass
Master links, coupling links and other components not cracked or deformedPass
Hooks not crackedPass
No makeshift links or fasteners made from bolts or rodsPass
No mechanical coupling links or low carbon steel links used to repair the chainPass

Readings

ReadingValueResult
Wire rope: randomly distributed broken wires in one rope lay
29 CFR 1910.184(f)(5)(i) wire rope removal (osha.gov) (https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.184), checked 2026-10-28
6 wiresPass
Wire rope: broken wires in one strand in one rope lay
29 CFR 1910.184(f)(5)(i) wire rope removal (osha.gov) (https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.184), checked 2026-10-28
3 wiresPass
Wire rope: outside wires worn or scraped by one-third of their original diameter
29 CFR 1910.184(f)(5)(ii) wire rope removal (osha.gov) (https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.184), checked 2026-10-28
NoPass
Wire rope: fiber core rope exposed above 200 °F
29 CFR 1910.184(f)(3) wire rope temperatures (osha.gov) (https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.184), checked 2026-10-28
NoPass
Hook opened past its normal throat, at the narrowest point
29 CFR 1910.184(e)(9)(ii) and (f)(5)(vi) hooks (osha.gov) (https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.184), checked 2026-10-28
9 %Pass
Hook twist from the plane of the unbent hook
29 CFR 1910.184(e)(9)(ii) and (f)(5)(vi) hooks (osha.gov) (https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.184), checked 2026-10-28
6 degreesPass
Chain: size at any point below the Table N-184-1 minimum
29 CFR 1910.184(e)(8) effect of wear (osha.gov) (https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.184), checked 2026-10-28
NoPass
Chain: heated above 1000 °F
29 CFR 1910.184(e)(6) chain temperatures (osha.gov) (https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.184), checked 2026-10-28
NoPass

Findings

SeverityFindingStatus
Remove from service permanentlySling, fastenings and attachments free of damage or defects. Failed at this inspection.Open

Signature

The signature drawn on the phone at the job prints here.

Next due

Thorough inspection (alloy steel chain)
29 CFR 1910.184(e)(3)(i) thorough periodic inspection (osha.gov) (https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.184), checked 2026-10-28
Oct 31, 2026Set by rule
Periodic inspection (other slings)Oct 31, 2026Set by your contract