A sample built from fictional records: every company, unit and date below is made up. Your reports carry your own records. Back to Tower Inspection
Sample company (fictional) · Tower InspectionDraft generated Oct 30, 2026
Tower inspection report
Aug 20, 2026
Record
| Company | Sample company (fictional) |
|---|
| Trade | Tower Inspection |
|---|
| Climb | Aug 20, 2026 |
|---|
Tower
| Owner's site number | Owner's site number 2 |
|---|
| FCC registration number (ASR) | AS-4137 |
|---|
| Structure | Self-supporting lattice |
|---|
| Height above ground | 8 ft |
|---|
| Guy levels | 8 |
|---|
| Structural inspection interval | 9 years |
|---|
| Painted for marking | No |
|---|
| Has obstruction lights | No |
|---|
| Light type | Red LED |
|---|
| How the lights are watched | Automatic indicator checked every 24 hours |
|---|
| Monitoring approved as self-diagnostic | No |
|---|
| Last light controls and alarm check | Aug 18, 2026 |
|---|
Climb
| Scheduled | Aug 20, 2026 |
|---|
| Completed | Aug 20, 2026 |
|---|
| Status | Completed |
|---|
Climb
| Registration number sign readable from the road or gate | Pass |
| Fence, gate, locks and signs in place | Fail |
| Foundations: cracks, settling, standing water, erosion | Pass |
| Ground leads attached, none cut or missing | Pass |
| Legs and braces: none bent, cracked or missing | Pass |
| Bolts and connections tight, none missing | Pass |
| Rust, flaking galvanizing or failed coating | Pass |
| Guy wires: broken strands, slack, end hardware secure | Pass |
| Guy anchors: shafts sound, no corrosion at grade | Pass |
| Antenna mounts secure and matching the drawings | Pass |
| Feed lines clamped, weatherproofed, not chafing | Pass |
| Ladder, step bolts and safety climb in working order | Pass |
| Obstruction lights, photocell and controller working | Pass |
| Paint bands clearly visible, where painted | Pass |
Readings
| Reading | Value | Result |
|---|
| Out of plumb at the top | Not taken | Recorded |
| Twist at the top | Not taken | Recorded |
Photos
Photos taken on the phone at the job print here, each captioned with what it shows.
Findings
| Severity | Finding | Status |
|---|
| Unsafe to climb | Fence, gate, locks and signs in place. Failed at this climb. | Open |
Signature
The signature drawn on the phone at the job prints here.
Next due
Light controls and alarm check 47 CFR 17.47(b) Inspection of antenna structure lights (Cornell LII) (https://www.law.cornell.edu/cfr/text/47/17.47), checked 2026-10-29 | Nov 18, 2026 | Set by rule |
| Structural inspection | Aug 20, 2035 | Set by your contract |